Estratti del catalogo
linda b | w e simp l i fy c o n s t r u c t i o n Product Selector
Aprire il catalogo a pagina 1Index Page 4-5: Single-Storey Buildings Steel structure Page 6-7: Multi-Storey Buildings Steel structure Page 8-9: LMR600 Roof systems Page 10-11: LPR1000 Roof systems Page 12-13: Polar - Spacetec - Multitec Page 14-15: LPA900 - LPD1000 Wall systems Ultimate watertightness Superior protection and performance Roof systems Combination of architectural aesthetics and energy-efficiency Page 16-17: Sinutec - Cassette Page 18-19: Polar – Sinutherm Page 20-21: Astrotherm insulation system Page 22-23: Mezzanines - Crane rail beams Wall systems Wall systems Cost-effective insulation concept for high...
Aprire il catalogo a pagina 3STEEL STRUCTURE Single-Storey Buildings The structure consists of columns and rafters made of welded or hot-rolled profiles, purlins and rails of cold-formed galvanized profiles. PRIMARY FRAMING: Primary framing consists of all the structural elements which transfer loads to the foundations. Main frames consist of built-up welded primary framing members, including flange bracings, connection bolts and anchor bolts. The bases of the intermediate frames are generally pinned, however, certain circumstances may dictate the use of fixed constructions. Protection: • All profiles are shot blasted...
Aprire il catalogo a pagina 4Fast-build, sheltered, short construction period – Preengineered solutions Large free span for optimum utilisation of the available floor Flexibility of use: to extend-, or to change the use of the building or to incorporate new installation Aesthetically pleasing A building that reflects the customer’s ambition 5
Aprire il catalogo a pagina 5STEEL STRUCTURE Multi-Storey Buildings The structure consists of columns, beams and stabilization elements. Beams and columns are made of hot-rolled or welded profiles, purlins and rails of cold-formed, galvanized profiles. STEEL STRUCTURE: Columns are fixed to the foundations by anchor bolts embedded in the concrete. Construction elements are connected to each other with galvanized, high-tensile steel bolts. All welded and hot-rolled construction elements are shot-blasted according to SA 2.5 and have an 80 micron primer coating in either blue or grey. Optionally, elements can be supplied...
Aprire il catalogo a pagina 6Integrated floor system (no protruding beams). Easy and low-cost installation of heating and ventilation systems Slim structure - Fast and easy erection - Reduced floor depths and overall height of the building Wide free space Flexibility in design, both during construction and in use 7
Aprire il catalogo a pagina 7LMR600 Standing seam roof mechanically fixed using unique sliding clips. TECHNICAL SPECIFICATIONS: • Consists of 600mm wide roll formed panels with a 70mm high corrugation • The panel is fixed with a clip allowing linear and lateral expansion and contraction • The flat side of the panel contains cross flutes improving the panel rigidity under foot traffic • The panels are produced in 0.66mm nominal thickness Aluzinc coated high tensile strength steel • Standing seam COLOURS AND COATINGS: • Aluzinc AZA (metallic coating) ACCESSORIES: In order to maintain the watertightness integrity and...
Aprire il catalogo a pagina 8Three effective systems SINGLE SKIN ROOF WITH OR WITHOUT ISOBLOC: • This system is the most cost-effective • The insulation is made of soft faced glass fiber providing good acoustical comfort • It is available with Isobloc and increased insulation thickness to improve overall thermal performance and reduction of thermal bridges Insulation (mm) U-value W/(m2 K) 40 60+ 80+ 100+ 120+ 0,96 0,67 0,57 0,51 0,50 += with Isobloc SINGLE SKIN ROOF WITH BRIDGE: • This system offers superior thermal efficiency and advanced condensation control by reducing the thermal bridge to a minimum. It also...
Aprire il catalogo a pagina 9LPR1000 Long span ribbed panel TECHNICAL SPECIFICATIONS: • Long span ribbed panel: coverage width 1000mm • 0.50mm core thickness, high tensile strength steel – S550 • Fixed to the structure with self drilling stainless steel screws COLOURS AND COATINGS: • Aluzinc (metallic coating) • Superpolyester 35 micron, AZA colour 01 38 35 ACCESSORIES: In order to maintain the watertightness integrity and aesthetic appearance, a full range of accessories adapted to LPR1000 roof systems have been developed: • Skylights • Translucent panels • Smoke vents • Ventilators • Polycarbonate vaults • Roof curbs...
Aprire il catalogo a pagina 10Three effective systems SINGLE SKIN ROOF WITH OR WITHOUT ISOBLOC: • This system is the most economical • The insulation is made of soft faced glass fiber providing a good acoustical comfort • It is available with Isobloc and increased insulation thickness to improve overall thermal performance and reduction of thermal bridges Insulation (mm) U-value W/(m2 K) 40 60 80 80+ 100+ 120+ 1,26 0,94 0,81 0,60 0,49 0,42 += with Isobloc SINGLE SKIN ROOF WITH BRIDGE: • This system offers superior thermal efficiency and advanced condensation control by reducing the thermal bridge to a minimum. It also...
Aprire il catalogo a pagina 11POLAR roof system The Polar roof is a complete roof system based on sandwich panels. It includes all necessary framed openings, fasteners and finishing flashings. Polar panels consist of two profiled ribbed coated steel panels, produced by cold roll forming, between which a CFC-free polyurethane foam is factory injected. Different insulation thicknesses and panel profiles are available within the Polar roof system. The U-values of the different products are those published by the panel manufacturers. TECHNICAL SPECIFICATIONS: Standard thicknesses: 40 to 130mm COLOURS AND COATINGS: Exterior...
Aprire il catalogo a pagina 12Spacetec/Multitec built-up roof systems Both low pitch roof systems consist of ribbed steel panels and allow the application of a built-up roof system. The Spacetec roof system is purlin-free, the panels are directly fixed to the upper flange of the primary framing. The Multitec roof system is fixed onto purlins. SPACETEC Spacetec does not require secondary framing. Slim, discrete compression tubes are installed on the lower flanges of the rafters to transmit the forces from the wind bracing tie rods. Framed openings are concealed within the depth of the roof panel. The thermal insulation...
Aprire il catalogo a pagina 13Tutti i cataloghi e le schede tecniche Lindab
-
voci di capitolato VENTILATION
20 Pagine
-
Lindab Group Q3 2017
22 Pagine
-
roof drainage system
24 Pagine
-
roof drainage system inspiration
16 Pagine
-
roof drainage system assembly
16 Pagine
-
Plenum box - H
1 Pagine
-
CRL
12 Pagine
-
Facade Cassettes
28 Pagine
-
sandwich wall panels
1 Pagine
-
Lindab Tile Effect Roofing
16 Pagine
-
Exterior Wall Profiles
14 Pagine
-
Standing Seam Roofing
14 Pagine
-
Garage doors
12 Pagine
-
Sandwich panels
10 Pagine
-
Rainwater systems
18 Pagine
-
Corporate brochure
15 Pagine
-
Fasteners
8 Pagine
-
Flashings
8 Pagine
-
Facade cassettes:
8 Pagine
-
Comfort Water
461 Pagine
-
Solutions for simplified construction
142 Pagine
Cataloghi archiviati
-
profiled sheeting
24 Pagine
-
Tile effect roofing
14 Pagine
-
Catalogue Ventilation 2010
678 Pagine
-
Lindab Group Presentation
36 Pagine